Concept Design

Commercial buildings & campuses

For facilities directors accountable for central plant, occupied buildings and controls contractors across a campus or portfolio.

Concept Design

Finding an air-handling fault that returns after the work order closes

A BMS alarm may clear after a controller reset while a damper or actuator continues to stick under load. The maintenance platform counts a completed visit, but the same zone generates fresh complaints on the next occupied day.

System landscape

Source evidence comes from bms trends and work orders. The proposed workflow sends the decision to facilities engineer.

Proposed architecture

Map the alarm and affected zones to the physical air handler. Compare approved commands, measured response, occupancy and visits across repeated operating periods. Route a recurrence to the responsible controls or mechanical contractor with the relevant trend window.

Event sequence Select a step for details
  1. Source recordsBMS trends and work orders
  2. ProcessingLink recurrent symptoms to equipment
  3. Decision ownerFacilities engineer
  4. Operational outputVerified repair outcome

Reliability and operating controls

The engineer establishes what constitutes a fault and what evidence demonstrates repair. Suppress repeated notifications while a job is active without suppressing the underlying evidence.

Illustrative operating scenario

A work order closes on Friday during light occupancy. On Monday, command and feedback diverge again. The facilities lead can reopen the same issue with evidence from both visits.

Delivery boundaries

The qualified controls engineer approves changes and commissioning. Facilities and energy managers agree the service and measurement conditions.

Expected business impact

Use post-repair trends to distinguish durable repairs from an alarm that cleared temporarily.

Acceptance test and handover

Check repeat callouts per asset and whether corrective work survived a comparable occupied period. Validate the asset-to-point mapping on site before expanding across buildings.

Industry evidence

The Australian Government describes the role of building management systems in supervising commercial HVAC equipment. Australian Government HVAC guidance on building management systems

BACnet is a building automation and control communications protocol. Installed device capabilities and local control sequences still need to be verified. BACnet International on building automation interoperability

Concept Design

Coordinating tenant after-hours cooling with zone and meter boundaries

A tenant can book after-hours air conditioning for one floor while the BMS controls several shared zones. The booking portal, building schedule and meter boundaries can describe different portions of the building.

System landscape

Source evidence comes from bookings, zones and calendars. The proposed workflow sends the decision to building operator.

Proposed architecture

Map each approved tenancy request to the served zones, plant schedule and metering boundary. Detect overlapping bookings and closures. Return the confirmed schedule or a specific exception to the tenant operations desk.

Event sequence Select a step for details
  1. Source recordsBookings, zones and calendars
  2. ProcessingResolve shared plant demand
  3. Decision ownerBuilding operator
  4. Operational outputConfirmed run and service record

Reliability and operating controls

A facilities operator approves unusual occupancies, changed zoning and manual extensions. Keep fire and life-safety controls separate. Record the actual run window alongside the requested one for review.

Illustrative operating scenario

Two tenants book overlapping evening hours on a shared air handler. The equipment needs one continuous operating period, while the building manager still needs separate records for each request.

Delivery boundaries

The qualified controls engineer approves changes and commissioning. Facilities and energy managers agree the service and measurement conditions.

Expected business impact

Reduce avoidable plant runtime and give tenants a consistent record of accepted after-hours service.

Acceptance test and handover

Rehearse simultaneous bookings, cancellation after start and a holiday schedule. Compare requested service, confirmed run and meter coverage before issuing tenant reporting.

Industry evidence

The Australian Government describes the role of building management systems in supervising commercial HVAC equipment. Australian Government HVAC guidance on building management systems

Concept Design

Verifying performance after a portfolio controls retrofit

A controls upgrade is completed in stages. Comparing utility bills before and after can mix changes in weather, floor occupancy, tenant fit-outs and the retrofit itself. The owner needs to know which sites merit the next investment.

System landscape

Source evidence comes from meters and change register. The proposed workflow sends the decision to energy manager.

Proposed architecture

Record commissioning dates, meter boundaries, plant configuration, weather and operating hours. Build a building-specific baseline and a register of material changes. Compare only periods the energy manager considers representative.

Event sequence Select a step for details
  1. Source recordsMeters and change register
  2. ProcessingBuild comparison periods
  3. Decision ownerEnergy manager
  4. Operational outputReproducible performance report

Reliability and operating controls

Flag missing meters, changed loads and manual overrides. The measurement specialist approves exclusions and the claim boundary. Keep separately measured and modelled figures visibly distinct.

Illustrative operating scenario

A building adds a laboratory during the verification period. The portfolio view shows the new load and its meter coverage so the reviewer can qualify the comparison.

Delivery boundaries

The qualified controls engineer approves changes and commissioning. Facilities and energy managers agree the service and measurement conditions.

Expected business impact

Give the owner a defensible comparison between buildings before funding further work.

Acceptance test and handover

Deliver the input data, baseline assumptions, excluded periods and sensitivity checks. A second reviewer should be able to reproduce the result building by building.

Industry evidence

The project team reports measured energy savings for nine campus plants after a full measurement and verification period. Exergenics · University of Melbourne central plants